Chosen class: III
-
Is your device INVASIVE or NON-INVASIVE?
You answered: Invasive
-
Is it NON-SURGICALLY INVASIVE or SURGICALLY INVASIVE?
You answered: Non-surgically invasive (this means that it enters in the human body but only through a body orifice and without piercing or cutting the skin or membranes)?
-
Is it NOT intended for connection to any active medical device?
You answered: No
-
It is intended for connection to an active medical device of class:
You answered: Class I active medical device
-
Is it intended for transient use?
You answered: Yes
-
Is your device ACTIVE?
You answered: Yes
-
Is it therapeutic?
You answered: Yes
-
Does it administer energy to or exchange energy with the human body?
You answered: Yes, in a potentially hazardous way (consider nature of energy, density of energy, site of the body).
-
Is it intended to emit ionizing radiation?
You answered: Yes
-
Is it intended for therapeutic radiology, including interventional radiology devices and devices which control or monitor such devices, or which directly influence their performance?
You answered: Yes
-
Is it intended to control or monitor a device that emits ionizing radiation, or does it directly influence the performance a device that emits ionizing radiation?
You answered: Yes
-
Is it intended to control or monitor the performance of active therapeutic class IIb devices, or intended directly to influence the performance of such devices?
You answered: Yes
-
Is it intended for controlling, monitoring or directly influencing the performance of active implantable devices?
You answered: No
-
Is it intended for diagnosis and monitoring?
You answered: No
-
Is it a software?
You answered: No
-
Is it intended to administer and/or remove medicinal products, body liquids or other substances to or from the body?
You answered: No
-
Does your device incorporate a medicinal product with an ancillary function?
You answered: No
-
Is it used for contraception or prevention of the transmission of sexually transmitted diseases?
You answered: No
-
Is it intended specifically to be used for disinfecting, cleaning, rinsing or, where appropriate, hydrating contact lenses?
You answered: No
-
Is it intended specifically to be used for disinfecting or sterilising medical devices that are not contact lenses ? NOTE: If it is only intended for cleaning and only by physical action, this rule does not apply.
You answered: Yes
-
Is it a disinfecting solution or washer-disinfector, intended specifically to be used for disinfecting invasive devices, as the end point of processing?
You answered: Yes
-
Is it specifically intended for recording of diagnostic images generated by X-ray radiation?
You answered: No
-
Is it manufactured utilizing tissues or cells of human or animal origin, or their derivatives, which are non-viable or rendered non-viable?
You answered: Yes
-
Does it incorporate or contain nanomaterials?
You answered: No
-
Is it intended to administer medicinal products by inhalation, being an invasive device with respect to body orifices, other than surgically invasive devices?
You answered: Yes
-
Does its mode of action have an essential impact on the efficacy and safety of the administered medicinal product?
You answered: No
-
Is it intended to treat life-threatening conditions?
You answered: No
-
Is it composed of substances or of combinations of substances that are intended to be introduced into the human body via a body orifice or applied to the skin and that are absorbed by or locally dispersed in the human body?
You answered: Yes
-
Is it or it products of metabolism, systemically absorbed by the human body in order to achieve the intended purpose?
You answered: Yes
-
Does it achieve its intended purpose in the stomach or lower gastrointestinal tract and it, or its products of metabolism, is systemically absorbed by the human body?
You answered: Yes
-
Is it applied to the skin or is it applied in the nasal or oral cavity as far as the pharynx, and achieve the intended purpose on those cavities?
You answered: No
-
Is it an active therapeutic device with an integrated or incorporated diagnostic function that includes an integrated or incorporated diagnostic function which significantly determines the patient management by the device (example: closed loop systems or automated external defibrillators)?
You answered: Yes